Description
Highlights
- EEPROM to store cal factors eliminates manual entry
- Wide frequency range from 10 MHz to 18 GHz
- Wide dynamic range from -35 dBm to +20 dBm
- Power linearity of less than 1%, excellent SWR of mismatch uncertainty and highly accurate power repeatability
- Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)
- SCPI codes compatible with 8480 series (option CFT)
Note: Option CFT is available as a replacement of legacy 8480 Series power sensors intended for cal factor manual entry and SCPI compatibility. Option CFT is not compatible with 43x and other obsolete power meters.
- SCPI codes compatible with E-Series sensor (standard option)
- Compatible with EPM (N1913/14A, E4418/19B), EPM-P (E4416/17A), P-Series (N1911/12A) power meters
Note: All N8480 series power sensors are not compatible with the Keysight 43x, E1416A, N8262A power meters, 5314x microwave counters and E7495x base station test set.
Additional information
| MODEL | N8481A(10MHz to 18GHz), N8482A(100kHz to 6GHz), N8485A(10MHz to 26.5GHz), N8487A(50MHz to 50GHz), N8488A(10MHz to 67GHz), N8481B(10MHz to 18GHz), N8482B(100kHz to 6GHz), N8481H(10MHz to 18GHz), N8482H(100kHz to 6GHz), N8486AR(26.5GHz to 40GHz), N8486AQ(33GHz to 50GHz), N8487S(DC to 50GHz), N8481S(DC to 18GHz) |
|---|---|
| Brand | KEYSIGHT |
Description
Highlights
- EEPROM to store cal factors eliminates manual entry
- Wide frequency range from 10 MHz to 18 GHz
- Wide dynamic range from -35 dBm to +20 dBm
- Power linearity of less than 1%, excellent SWR of mismatch uncertainty and highly accurate power repeatability
- Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)
- SCPI codes compatible with 8480 series (option CFT)
Note: Option CFT is available as a replacement of legacy 8480 Series power sensors intended for cal factor manual entry and SCPI compatibility. Option CFT is not compatible with 43x and other obsolete power meters.
- SCPI codes compatible with E-Series sensor (standard option)
- Compatible with EPM (N1913/14A, E4418/19B), EPM-P (E4416/17A), P-Series (N1911/12A) power meters
Note: All N8480 series power sensors are not compatible with the Keysight 43x, E1416A, N8262A power meters, 5314x microwave counters and E7495x base station test set.
Additional information
| MODEL | N8481A(10MHz to 18GHz), N8482A(100kHz to 6GHz), N8485A(10MHz to 26.5GHz), N8487A(50MHz to 50GHz), N8488A(10MHz to 67GHz), N8481B(10MHz to 18GHz), N8482B(100kHz to 6GHz), N8481H(10MHz to 18GHz), N8482H(100kHz to 6GHz), N8486AR(26.5GHz to 40GHz), N8486AQ(33GHz to 50GHz), N8487S(DC to 50GHz), N8481S(DC to 18GHz) |
|---|---|