Micsig DP Series High impedance High Voltage Differential Probe

$268.00 – $1,349.00

  • Bandwidth: 100MHz / 150MHz / 200MHz / 300MHz / 400MHz / 500MHz
  • Max. Voltage: 700Vpk / 1500Vpk / 3000Vpk / 7000Vpk

Micsig DP Series High impedance High Voltage Differential Probe

$268.00 – $1,349.00

  • Bandwidth: 100MHz / 150MHz / 200MHz / 300MHz / 400MHz / 500MHz
  • Max. Voltage: 700Vpk / 1500Vpk / 3000Vpk / 7000Vpk
Chat on WhatsApp

Description

Micsig dp series

With standard BNC interface, the DP series can work with any oscilloscope; probe body is only 2CM thick, protected by metal housing, achieves strong anti-interference ability. One-press auto Zero, dual-range and overload alarm design. High impedance designed, the single-ended impedance of the input end to the signal output BNC interface >8MΩ, single-ended capacitance <8pF, meets various safety test requirements. 5MHz bandwidth limit function can effectively filter out high-frequency noise and interference, ideal for switching power supplies, various high-frequency and high-voltage floating or isolated signal tests.

differential probe

Excellent Bandwidth Flatness-The DP series probe has excellent bandwidth flatness, amplitude fluctuation less than 0.5dB within its half bandwidth range, even in high frequency bands can also maintain high accuracy.

differential probe

High Accuracy, High CMRR-High input impedance and low input capacitance, minimized load effect, greatly improved the accuracy of the differential signal. High common mode rejection capability, able to meet floating measurements of large common mode voltage at high frequencies. CH1: @ 100KHz, 207.7V, output common mode signal amplitude 94.62mV, CMRR > -60dB.

Low Noise-DP3000 test results: under 1000X, noise at full bandwidth is 254.8μVrms.

differential probe

5MHz Bandwidth Limit

(only available on 100MHz ~ 200MHz versions,except DP7000)

When measuring FET switching frequency in most switching power supplies, DP probe effectively eliminates high-frequency noise.

 

Quick Zero-Short-circuit the test leads, press Zero button, the probe can be zeroed very fast.

 

Dual Range Selection-Improves signal-to-noise ratio, meet more test requirements.

 

BNC Interface-Standard BNC interface, work with any oscilloscope.

differential probe

Overvoltage Alarm-LED flashes, buzzer “beeps” rapidly, indicating an over-range alert.

 

Compact & Exquisite-Much smaller than traditional differential probes.

differential probe

 

Applications

● Floating measurements

● High voltage isolation measurements

● Switching power supply design

● Power converter design

● Inverter, UPS power supply

● Welding, electroplating power supply

● Electronic ballast design

● Motor drive design

● Induction heating, induction cooker

● CRT display design

● Low-voltage electrical appliances

● Electronic power and electric drive experiments

 

Key Specifications

Model Bandwidth Differential Voltage (DC+AC PK) Max. CMRR Input impedance
DP700 100MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-60dB
10MHz: >-30dB
100MHz: >-26dB
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP1500 150V(50X)
1500V(500X)
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP3000 300V(100X)
3000V(1000X)
20MΩ / 1.5pF(differential)
10MΩ / 3pF(each input to ground)
DP7000 700V(100X)
7000V(1000X)
60MΩ / 0.78pF(differential)
30MΩ / 1.6pF(each input to ground)
DP701 150MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-60dB
10MHz: >-30dB
100MHz: >-26dB
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP1501 150V(50X)
1500V(500X)
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP3001 300V(100X)
3000V(1000X)
20MΩ / 1.5pF(differential)
10MΩ / 3pF(each input to ground)
DP702 200MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-60dB
10MHz: >-30dB
100MHz: >-26dB
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP1502 150V(50X)
1500V(500X)
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP3002 300V(100X)
3000V(1000X)
20MΩ / 1.5pF(differential)
10MΩ / 3pF(each input to ground)
DP703 300MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-70dB
20MHz: >-40dB
120MHz: >-26dB
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP1503 150V(50X)
1500V(500X)
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP3003 300V(100X)
3000V(1000X)
20MΩ / 0.5pF(differential)
10MΩ / 1pF(each input to ground)
DP704 400MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-70dB
20MHz: >-40dB
120MHz: >-26dB
16MΩ / 0.5pF( differential)
8MΩ / 1pF(each input to ground)
DP1504 150V(50X)
1500V(500X)
16MΩ / 0.5pF( differential)
8MΩ / 1pF(each input to ground)
DP3004 300V(100X)
3000V(1000X)
20MΩ / 0.5pF( differential)
10MΩ / 1pF(each input to ground)
DP705 500MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-70dB
20MHz: >-40dB
120MHz: >-26dB
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP1505 150V(50X)
1500V(500X)
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP3005 300V(100X)
3000V(1000X)
20MΩ / 0.5pF(differential)
10MΩ / 1pF(each input to ground)

 

*The previous model DP10007 has been upgraded to DP700.

*The previous model DP10013 has been upgraded to DP1500.

*The previous model DP20003 has been upgraded to DP3000.

Note: These models have not only been upgraded in performance (see parameter table), but also in appearance, which has been newly designed and made more compact and exquisite. When placing orders, please handle them according to the new model numbers.

Additional information

model

DP700, DP1500, DP3000, DP7000, DP701, DP1501, DP3001, DP702, DP1502, DP3002, DP703, DP1503, DP3003, DP704, DP1504, DP3004, DP705, DP1505, DP3005

Brand

MICSIG

Reviews

There are no reviews yet.

Be the first to review “Micsig DP Series High impedance High Voltage Differential Probe”

Your email address will not be published. Required fields are marked *

Description

Micsig dp series

With standard BNC interface, the DP series can work with any oscilloscope; probe body is only 2CM thick, protected by metal housing, achieves strong anti-interference ability. One-press auto Zero, dual-range and overload alarm design. High impedance designed, the single-ended impedance of the input end to the signal output BNC interface >8MΩ, single-ended capacitance <8pF, meets various safety test requirements. 5MHz bandwidth limit function can effectively filter out high-frequency noise and interference, ideal for switching power supplies, various high-frequency and high-voltage floating or isolated signal tests.

differential probe

Excellent Bandwidth Flatness-The DP series probe has excellent bandwidth flatness, amplitude fluctuation less than 0.5dB within its half bandwidth range, even in high frequency bands can also maintain high accuracy.

differential probe

High Accuracy, High CMRR-High input impedance and low input capacitance, minimized load effect, greatly improved the accuracy of the differential signal. High common mode rejection capability, able to meet floating measurements of large common mode voltage at high frequencies. CH1: @ 100KHz, 207.7V, output common mode signal amplitude 94.62mV, CMRR > -60dB.

Low Noise-DP3000 test results: under 1000X, noise at full bandwidth is 254.8μVrms.

differential probe

5MHz Bandwidth Limit

(only available on 100MHz ~ 200MHz versions,except DP7000)

When measuring FET switching frequency in most switching power supplies, DP probe effectively eliminates high-frequency noise.

 

Quick Zero-Short-circuit the test leads, press Zero button, the probe can be zeroed very fast.

 

Dual Range Selection-Improves signal-to-noise ratio, meet more test requirements.

 

BNC Interface-Standard BNC interface, work with any oscilloscope.

differential probe

Overvoltage Alarm-LED flashes, buzzer “beeps” rapidly, indicating an over-range alert.

 

Compact & Exquisite-Much smaller than traditional differential probes.

differential probe

 

Applications

● Floating measurements

● High voltage isolation measurements

● Switching power supply design

● Power converter design

● Inverter, UPS power supply

● Welding, electroplating power supply

● Electronic ballast design

● Motor drive design

● Induction heating, induction cooker

● CRT display design

● Low-voltage electrical appliances

● Electronic power and electric drive experiments

 

Key Specifications

Model Bandwidth Differential Voltage (DC+AC PK) Max. CMRR Input impedance
DP700 100MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-60dB
10MHz: >-30dB
100MHz: >-26dB
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP1500 150V(50X)
1500V(500X)
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP3000 300V(100X)
3000V(1000X)
20MΩ / 1.5pF(differential)
10MΩ / 3pF(each input to ground)
DP7000 700V(100X)
7000V(1000X)
60MΩ / 0.78pF(differential)
30MΩ / 1.6pF(each input to ground)
DP701 150MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-60dB
10MHz: >-30dB
100MHz: >-26dB
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP1501 150V(50X)
1500V(500X)
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP3001 300V(100X)
3000V(1000X)
20MΩ / 1.5pF(differential)
10MΩ / 3pF(each input to ground)
DP702 200MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-60dB
10MHz: >-30dB
100MHz: >-26dB
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP1502 150V(50X)
1500V(500X)
16MΩ / 1.5pF(differential)
8MΩ / 3pF(each input to ground)
DP3002 300V(100X)
3000V(1000X)
20MΩ / 1.5pF(differential)
10MΩ / 3pF(each input to ground)
DP703 300MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-70dB
20MHz: >-40dB
120MHz: >-26dB
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP1503 150V(50X)
1500V(500X)
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP3003 300V(100X)
3000V(1000X)
20MΩ / 0.5pF(differential)
10MΩ / 1pF(each input to ground)
DP704 400MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-70dB
20MHz: >-40dB
120MHz: >-26dB
16MΩ / 0.5pF( differential)
8MΩ / 1pF(each input to ground)
DP1504 150V(50X)
1500V(500X)
16MΩ / 0.5pF( differential)
8MΩ / 1pF(each input to ground)
DP3004 300V(100X)
3000V(1000X)
20MΩ / 0.5pF( differential)
10MΩ / 1pF(each input to ground)
DP705 500MHz 70V(20X)
700V(200X)
DC:>-80dB
100kHz: >-70dB
20MHz: >-40dB
120MHz: >-26dB
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP1505 150V(50X)
1500V(500X)
16MΩ / 0.5pF(differential)
8MΩ / 1pF(each input to ground)
DP3005 300V(100X)
3000V(1000X)
20MΩ / 0.5pF(differential)
10MΩ / 1pF(each input to ground)

 

*The previous model DP10007 has been upgraded to DP700.

*The previous model DP10013 has been upgraded to DP1500.

*The previous model DP20003 has been upgraded to DP3000.

Note: These models have not only been upgraded in performance (see parameter table), but also in appearance, which has been newly designed and made more compact and exquisite. When placing orders, please handle them according to the new model numbers.

Additional information

model

DP700, DP1500, DP3000, DP7000, DP701, DP1501, DP3001, DP702, DP1502, DP3002, DP703, DP1503, DP3003, DP704, DP1504, DP3004, DP705, DP1505, DP3005

Brand

MICSIG

Reviews

There are no reviews yet.

Be the first to review “Micsig DP Series High impedance High Voltage Differential Probe”

Your email address will not be published. Required fields are marked *

free shipping

All products are free shipping

24H/7D support

The best service for you

100% Authentic

Original factory production

free shipping

All products are free shipping

24H/7D support

The best service for you

100% Authentic

Original factory production