Ceyear 4024 Series Spectrum Analyzer

$7,539.00 – $57,200.00

0% Off

  • Frequency range:9kHz to 67GHz
  • SSB phase noise(1GHz carrier@100kHz offset)
  • Low displayed average noise level: -163dBm@1Hz RBW(typical)

Ceyear 4024 Series Spectrum Analyzer

$7,539.00 – $57,200.00

0% Off

  • Frequency range:9kHz to 67GHz
  • SSB phase noise(1GHz carrier@100kHz offset)
  • Low displayed average noise level: -163dBm@1Hz RBW(typical)
Chat on WhatsApp

Description

4024 Series Spectrum Analyzer

4024 series spectrum analyzer possesses many advantages: wide frequency range, high performance, high sweep speed, various functions, and easy operation. In terms of performance index, it has advantages of excellent displayed average noise level, low phase noise, and high sweep speed. In terms of measurement functions, it has measurement functions of spectrum analyzer, interference analyzer, AM/FM/PM analyzer, power meter, channel scanner etc., as well as intelligent measurement functions of channel power, occupied bandwidth, adjacent-channel power, tune & listen, emission mask, and carrier-to-noise ratio etc. 4024 adopts the integrated design of 8.4 inch LCD and capacitive touch screen, which improves the display definition and operation convenient. It is handheld, compact and light, with flexible power supply, which is very suitable for field work.

4024 can be used for signal and equipment test in the fields of aerospace, microwave & satellite communication, radio communication, radar monitoring, electronic countermeasures & reconnaissance, and precision guidance.

Features

•Wide frequency range: from 9kHz to 67GHz, 9 models

•Low displayed average noise level: -163dBm@1Hz RBW(typical)

•Excellent phase noise performance:

-112dBc/Hz@100kHz frequency offset@1GHz carrier (4024A/B/C)

-106dBc/Hz@100kHz frequency offset@1GHz carrier (4024D/E/F/G/H/L)

•High sweep speed: for 1GHz span, shortest sweep time <20ms

•Resolution bandwidth: 1Hz~10MHz

•Full-band pre-amplifier: standard configuration

•Various measurement functions: spectrum analyzer, interference analyzer (spectrogram, RSSI), AM/FM/PM analyzer, channel scanner, high accuracy power meter, signal analyzer etc.

•Various intelligent measurement functions: field strength measurement, channel power, occupied bandwidth, adjacent-channel power ratio, tune&listen,     carrier- to-noise ratio, emission mask•Various auxiliary test interface: 10MHz reference input/output interface, GPS antenna interface, zero span IF output interface, external triggering input interface etc.•Easy & convenient user operation: 8.4 inch high definition LCD and large font display, convenient capacitive touch screen operation, combination of LCD and touch screen, various display modes etc.

•Working temperature range: -10℃~50℃, Power supplied by battery or adapter

Model 4024A/B/C/D/E/F/G/H/L
Frequency Range 4024A:9kHz~4GHz        4024B:9kHz~6.5GHz

4024C:9kHz~9GHz        4024D:9kHz~20GHz

4024E:9kHz~26.5GHz      4024F:9kHz~32GHz

4024G:9kHz~44GHz       4024H:9kHz~50GHz

4024L:9kHz~67GHz

Tuning Resolution:1Hz

Frequency Reference Frequency: 10MHz

Aging: ±0.5ppm/Year

Initial Frequency Accuracy: ±0.3ppm

Temperature Stability:±0.1ppm(-10~50℃,   Comparative to 25℃)

Sweep Time Range: 10μs~600s   (Zero Span)

Accuracy: ±2.00% (Zero Span)

Frequency Readout Accuracy ±(Frequency Readout× frequency   Reference +2%× Span +10%× Resolution Bandwidth)
Frequency Span Range: 100Hz~Upper   Frequency Limit of Corresponding Model or 0Hz

Accuracy: ±2.0%

Resolution Bandwidth 1Hz~10MHz   (1-3 Times of Stepping)
Video Bandwidth 1Hz~10MHz   (1-3 Times of Stepping)
SSB Phase Noise

(Carrier 1GHz)

4024A/B/C:

≤-108dBc/Hz@ Frequency Offset 10kHz

≤-112dBc/Hz@ Frequency Offset 100kHz

≤-118dBc/Hz@ Frequency Offset 1MHz

≤-129dBc/Hz@ Frequency Offset 10MHz

4024D/E/F/GH/L:

≤-102dBc/Hz@ Frequency Offset 10kHz

≤-106dBc/Hz@ Frequency Offset 100kHz

≤-111dBc/Hz@ Frequency Offset 1MHz

≤-123dBc/Hz@ Frequency Offset 10MHz

Displayed   Average Noise Level

(input   port is connected with a 50Ω   load, 0dB input attenuation, average detection, logarithm of video type, RBW   normalized to 1Hz, tracking source off, 20℃~30℃)

4024A/B/C:

Pre-amp Off:

≤-140dBm(10MHz~3GHz)

≤-138dBm(3GHz~9GHz)

 

Pre-amp On:

≤-160dBm(10MHz~3GHz)

≤-157dBm(3GHz~9GHz)

4024D/E/F/G:

Pre-amp Off:

≤-138dBm(10MHz~20GHz)

≤-135dBm(20GHz~32GHz)

≤-127dBm(32GHz~40GHz)

Pre-amp On:

≤-157dBm(10MHz~20GHz)

≤-154dBm(20GHz~32GHz)

≤-148dBm(32GHz~40GHz)

4024H/L:

Pre-amp Off:

≤-135dBm(10MHz~20GHz)    ≤-134dBm(20GHz~32GHz)

≤-129dBm(32GHz~40GHz)    ≤-120dBm(40GHz~46GHz)

≤-114dBm(46GHz~50GHz)    ≤-114dBm(50GHz~60GHz)

≤-100dBm(60GHz~67GHz)

 

Pre-amp On:

≤-153dBm(10MHz~20GHz)    ≤-152dBm(20GHz~32GHz)

≤-147dBm(32GHz~40GHz)    ≤-142dBm(40GHz~46GHz)

≤-132dBm(46GHz~50GHz)    ≤-132dBm(50GHz~60GHz)

≤-118dBm(60GHz~67GHz)

Residual Response

 

4024A/B/C   (exceptional frequency: 3.2GHz):

Pre-amp   Off:

≤-82dBm(10MHz~9GHz)

Pre-amp   On:

≤-95dBm(10MHz~9GHz)

4024D/E/F/G   (exceptional frequency: 3.2GHz):

Pre-amp Off:

≤-90dBm(10MHz~13GHz)     ≤-85dBm (13GHz~20GHz)

≤-80dBm (20GHz~44GHz)

Pre-amp On:

≤-100dBm (10MHz~32GHz)    ≤-95dBm (32GHz~44GHz)

Second Harmonic Distortion

(0dB attenuation, -30dBm input signal)

4024A/B/C/H/L: <-65dBc

4024D/E/F/G: <-60dBc

Absolute Amplitude Accuracy

(input signal 0dBm~-50dBm, all   settings are automatic couplings, 20℃~30℃,   30 minutes of preheating)

±1.8dB (10MHz~13GHz)

±2.3dB (13GHz~40GHz)

±2.7dB (40GHz~50GHz)

±3.0dB (50GHz~67GHz)

Input Attenuator 4024A/B/C/H/L:

Attenuation Range: 0dB~30dB,   5dB Stepping

4024D/E/F/G:

Attenuation Range: 0dB~50dB,   10dB Stepping

Maximum Continuous Input 4024A/B/C/H/L:

+27dBm Peak Typical(≥10dB Attenuation)

+20dBm Peak Typical(<10dB   Attenuation)

+10dBm Peak Typical(Pre-amp On)

4024D/E/F/G:

+30dBm Peak Typical(≥10dB Attenuation)

+23dBm Peak Typical(<10dB   Attenuation)

+13dBm Peak Typical(Pre-amp On)

Reference Level Range: -120dBm~+30dBm

Conversion Uncertainty: ±1.20dB

Dimension 314mm (W)×218mm (H)×91mm (D)   (Excluding Handle, Stand)

338mm(W)×218mm (H)×100mm (D) (Including Handle, Stand)

Weight 4024A/B/C: ≤4.5kg 4024D/E/F/G:

≤5.1kg

4024H/L: ≤5.3kg
Working Temperature -10℃~+50℃   (the battery operation temperature is 0℃~+45℃)
Storage Temperature -40℃~+70℃   (the battery storage temperature is -20℃~+60℃)
Electromagnetic Compatibility Conforms to GJB3947A-2009 3.9.1   Requirements
Battery operation time 4024A/B/C: about 3h 4024D/E/F/G:

about 2.5h

4024H/L:

2h (typical)

Power Consumption 4024A/B/C: ≤25W 4024D/E/F/G:   ≤33W 4024H/L: ≤38W
Test Interface RF input:

4024A/B/C/D/E: Type-N Connector(female)

4024F/G: 2.4mm Connector(male)

4024H/L: 1.85mm Connector(male)

RF output:

Test interface of tracking generator   option for 4024A/B/C:

Type-N Connector(female)

Other Interfaces 10MHz Reference Input/Output: BNC (female)   Connector

External Triggering Input: BNC (female)   Connector

IF Output: BNC (female) Connector

GPS Antenna Input: BNC (female)   Connector

Additional information

Model

4024A:9kHz~4GHz, 4024B:9kHz~6.5GHz, 4024C:9kHz~9GHz, 4024D:9kHz~20GHz, 4024E:9kHz~26.5GHz, 4024F:9kHz~32GHz, 4024G:9kHz~44GHz, 4024H:9kHz~50GHz, 4024L:9kHz~67GHz

Brand

Ceyear

Reviews

There are no reviews yet.

Be the first to review “Ceyear 4024 Series Spectrum Analyzer”

Your email address will not be published. Required fields are marked *

Description

4024 Series Spectrum Analyzer

4024 series spectrum analyzer possesses many advantages: wide frequency range, high performance, high sweep speed, various functions, and easy operation. In terms of performance index, it has advantages of excellent displayed average noise level, low phase noise, and high sweep speed. In terms of measurement functions, it has measurement functions of spectrum analyzer, interference analyzer, AM/FM/PM analyzer, power meter, channel scanner etc., as well as intelligent measurement functions of channel power, occupied bandwidth, adjacent-channel power, tune & listen, emission mask, and carrier-to-noise ratio etc. 4024 adopts the integrated design of 8.4 inch LCD and capacitive touch screen, which improves the display definition and operation convenient. It is handheld, compact and light, with flexible power supply, which is very suitable for field work.

4024 can be used for signal and equipment test in the fields of aerospace, microwave & satellite communication, radio communication, radar monitoring, electronic countermeasures & reconnaissance, and precision guidance.

Features

•Wide frequency range: from 9kHz to 67GHz, 9 models

•Low displayed average noise level: -163dBm@1Hz RBW(typical)

•Excellent phase noise performance:

-112dBc/Hz@100kHz frequency offset@1GHz carrier (4024A/B/C)

-106dBc/Hz@100kHz frequency offset@1GHz carrier (4024D/E/F/G/H/L)

•High sweep speed: for 1GHz span, shortest sweep time <20ms

•Resolution bandwidth: 1Hz~10MHz

•Full-band pre-amplifier: standard configuration

•Various measurement functions: spectrum analyzer, interference analyzer (spectrogram, RSSI), AM/FM/PM analyzer, channel scanner, high accuracy power meter, signal analyzer etc.

•Various intelligent measurement functions: field strength measurement, channel power, occupied bandwidth, adjacent-channel power ratio, tune&listen,     carrier- to-noise ratio, emission mask•Various auxiliary test interface: 10MHz reference input/output interface, GPS antenna interface, zero span IF output interface, external triggering input interface etc.•Easy & convenient user operation: 8.4 inch high definition LCD and large font display, convenient capacitive touch screen operation, combination of LCD and touch screen, various display modes etc.

•Working temperature range: -10℃~50℃, Power supplied by battery or adapter

Model 4024A/B/C/D/E/F/G/H/L
Frequency Range 4024A:9kHz~4GHz        4024B:9kHz~6.5GHz

4024C:9kHz~9GHz        4024D:9kHz~20GHz

4024E:9kHz~26.5GHz      4024F:9kHz~32GHz

4024G:9kHz~44GHz       4024H:9kHz~50GHz

4024L:9kHz~67GHz

Tuning Resolution:1Hz

Frequency Reference Frequency: 10MHz

Aging: ±0.5ppm/Year

Initial Frequency Accuracy: ±0.3ppm

Temperature Stability:±0.1ppm(-10~50℃,   Comparative to 25℃)

Sweep Time Range: 10μs~600s   (Zero Span)

Accuracy: ±2.00% (Zero Span)

Frequency Readout Accuracy ±(Frequency Readout× frequency   Reference +2%× Span +10%× Resolution Bandwidth)
Frequency Span Range: 100Hz~Upper   Frequency Limit of Corresponding Model or 0Hz

Accuracy: ±2.0%

Resolution Bandwidth 1Hz~10MHz   (1-3 Times of Stepping)
Video Bandwidth 1Hz~10MHz   (1-3 Times of Stepping)
SSB Phase Noise

(Carrier 1GHz)

4024A/B/C:

≤-108dBc/Hz@ Frequency Offset 10kHz

≤-112dBc/Hz@ Frequency Offset 100kHz

≤-118dBc/Hz@ Frequency Offset 1MHz

≤-129dBc/Hz@ Frequency Offset 10MHz

4024D/E/F/GH/L:

≤-102dBc/Hz@ Frequency Offset 10kHz

≤-106dBc/Hz@ Frequency Offset 100kHz

≤-111dBc/Hz@ Frequency Offset 1MHz

≤-123dBc/Hz@ Frequency Offset 10MHz

Displayed   Average Noise Level

(input   port is connected with a 50Ω   load, 0dB input attenuation, average detection, logarithm of video type, RBW   normalized to 1Hz, tracking source off, 20℃~30℃)

4024A/B/C:

Pre-amp Off:

≤-140dBm(10MHz~3GHz)

≤-138dBm(3GHz~9GHz)

 

Pre-amp On:

≤-160dBm(10MHz~3GHz)

≤-157dBm(3GHz~9GHz)

4024D/E/F/G:

Pre-amp Off:

≤-138dBm(10MHz~20GHz)

≤-135dBm(20GHz~32GHz)

≤-127dBm(32GHz~40GHz)

Pre-amp On:

≤-157dBm(10MHz~20GHz)

≤-154dBm(20GHz~32GHz)

≤-148dBm(32GHz~40GHz)

4024H/L:

Pre-amp Off:

≤-135dBm(10MHz~20GHz)    ≤-134dBm(20GHz~32GHz)

≤-129dBm(32GHz~40GHz)    ≤-120dBm(40GHz~46GHz)

≤-114dBm(46GHz~50GHz)    ≤-114dBm(50GHz~60GHz)

≤-100dBm(60GHz~67GHz)

 

Pre-amp On:

≤-153dBm(10MHz~20GHz)    ≤-152dBm(20GHz~32GHz)

≤-147dBm(32GHz~40GHz)    ≤-142dBm(40GHz~46GHz)

≤-132dBm(46GHz~50GHz)    ≤-132dBm(50GHz~60GHz)

≤-118dBm(60GHz~67GHz)

Residual Response

 

4024A/B/C   (exceptional frequency: 3.2GHz):

Pre-amp   Off:

≤-82dBm(10MHz~9GHz)

Pre-amp   On:

≤-95dBm(10MHz~9GHz)

4024D/E/F/G   (exceptional frequency: 3.2GHz):

Pre-amp Off:

≤-90dBm(10MHz~13GHz)     ≤-85dBm (13GHz~20GHz)

≤-80dBm (20GHz~44GHz)

Pre-amp On:

≤-100dBm (10MHz~32GHz)    ≤-95dBm (32GHz~44GHz)

Second Harmonic Distortion

(0dB attenuation, -30dBm input signal)

4024A/B/C/H/L: <-65dBc

4024D/E/F/G: <-60dBc

Absolute Amplitude Accuracy

(input signal 0dBm~-50dBm, all   settings are automatic couplings, 20℃~30℃,   30 minutes of preheating)

±1.8dB (10MHz~13GHz)

±2.3dB (13GHz~40GHz)

±2.7dB (40GHz~50GHz)

±3.0dB (50GHz~67GHz)

Input Attenuator 4024A/B/C/H/L:

Attenuation Range: 0dB~30dB,   5dB Stepping

4024D/E/F/G:

Attenuation Range: 0dB~50dB,   10dB Stepping

Maximum Continuous Input 4024A/B/C/H/L:

+27dBm Peak Typical(≥10dB Attenuation)

+20dBm Peak Typical(<10dB   Attenuation)

+10dBm Peak Typical(Pre-amp On)

4024D/E/F/G:

+30dBm Peak Typical(≥10dB Attenuation)

+23dBm Peak Typical(<10dB   Attenuation)

+13dBm Peak Typical(Pre-amp On)

Reference Level Range: -120dBm~+30dBm

Conversion Uncertainty: ±1.20dB

Dimension 314mm (W)×218mm (H)×91mm (D)   (Excluding Handle, Stand)

338mm(W)×218mm (H)×100mm (D) (Including Handle, Stand)

Weight 4024A/B/C: ≤4.5kg 4024D/E/F/G:

≤5.1kg

4024H/L: ≤5.3kg
Working Temperature -10℃~+50℃   (the battery operation temperature is 0℃~+45℃)
Storage Temperature -40℃~+70℃   (the battery storage temperature is -20℃~+60℃)
Electromagnetic Compatibility Conforms to GJB3947A-2009 3.9.1   Requirements
Battery operation time 4024A/B/C: about 3h 4024D/E/F/G:

about 2.5h

4024H/L:

2h (typical)

Power Consumption 4024A/B/C: ≤25W 4024D/E/F/G:   ≤33W 4024H/L: ≤38W
Test Interface RF input:

4024A/B/C/D/E: Type-N Connector(female)

4024F/G: 2.4mm Connector(male)

4024H/L: 1.85mm Connector(male)

RF output:

Test interface of tracking generator   option for 4024A/B/C:

Type-N Connector(female)

Other Interfaces 10MHz Reference Input/Output: BNC (female)   Connector

External Triggering Input: BNC (female)   Connector

IF Output: BNC (female) Connector

GPS Antenna Input: BNC (female)   Connector

Additional information

Model

4024A:9kHz~4GHz, 4024B:9kHz~6.5GHz, 4024C:9kHz~9GHz, 4024D:9kHz~20GHz, 4024E:9kHz~26.5GHz, 4024F:9kHz~32GHz, 4024G:9kHz~44GHz, 4024H:9kHz~50GHz, 4024L:9kHz~67GHz

Brand

Ceyear

Reviews

There are no reviews yet.

Be the first to review “Ceyear 4024 Series Spectrum Analyzer”

Your email address will not be published. Required fields are marked *

free shipping

All products are free shipping

24H/7D support

The best service for you

100% Authentic

Original factory production

free shipping

All products are free shipping

24H/7D support

The best service for you

100% Authentic

Original factory production